ACASISHDMI CableACASIS 阿卡西斯 HDMI 2.0 影音傳輸線 2M | 支援 4K@60Hz 高畫質、18Gbps 高頻寬抗干擾、原廠公司貨Price on requestProject QuoteAdd to quote
ACASISSwitch USBC CableACASIS 4K 144Hz 掌機專用高更新率投屏線 | 支援 HDR 影像技術、音畫同步零延遲、鍍金抗氧化接頭、原廠公司貨Price on requestProject QuoteAdd to quote
ACASISHDMI/DP USB-C CableACASIS 阿卡西斯 Type-C 轉 HDMI/DP 4K 影音投屏線 | 24K鍍金接頭、高密度編織線身、鋁合金散熱外殼、原廠公司貨Price on requestProject QuoteAdd to quote
DellDP CableDELL 原廠 DP 1.4 螢幕傳輸線 1.8M | 支援 8K/4K 高更新率、按壓式安全卡扣、電競影音專用、原廠公司貨Price on requestProject QuoteAdd to quote
KYORITSUKEW 2500KYORITSU KEW 2500 DC Milliamp Clamp Meter | Measures 4–20 mA without breaking the loop, 0.01 mA resolution, φ6 mm jaw, recorder outputDC 20 / 100 mA auto-ranging; 0.01–120.0 mA; 0.01 mA resolution±0.2%rdg±5dgt (0.00–21.49 mA); φ6 mm jawDual display of mA and 4–20 mA %; recorder output DC 1000 mV / 100 mA; IP40Price on requestProject QuoteAdd to quote
KYORITSU6516KYORITSU KEW 6516 Multifunction Installation Tester | Insulation, loop impedance, RCD (incl. Type B, EV), earth, continuity, phase rotation, 3.5-inch color LCDInsulation 100 / 250 / 500 / 1000 V; loop impedance incl. ATT no-trip test; PSC / PFCRCD Type AC, A, F, B (general / time-delayed) and EV; earth 2 / 3-wire; continuity 200 mA / 15 mA3.5-inch color LCD; CAT IV 300 V / CAT III 600 V; IP40; USBPrice on requestProject QuoteAdd to quote
KYORITSU5410KYORITSU KEW 5410 RCD Tester | Trip time ×1/2, ×1, ×5, trip current by auto Ramp, IΔn 15–500 mA, IP54Trip time ×1/2, ×1, ×5; IΔn 15 / 30 / 50 / 100 / 200 / 500 mAAuto Ramp 40–110% IΔn; test stops when touch voltage reaches AC 50 VVoltage 80–450 V; CAT III 300 V / CAT II 400 V; IP54Price on requestProject QuoteAdd to quote
KYORITSU3121BKYORITSU KEW 3121B Analog High-Voltage Insulation Tester | DC 2500 V, 2 / 100 GΩ auto-ranging, CAT IV 300 V / CAT III 600 V, hard case includedDC 2500 V; 2 GΩ / 100 GΩ auto-ranging, LED indication0.1–50 GΩ ±5%rdg; other ranges ±10%rdg or 0.5% of scale lengthCAT IV 300 V / CAT III 600 V; 8 × C batteries; approx. 1.6 kgPrice on requestProject QuoteAdd to quote
KYORITSU3025BKYORITSU KEW 3025B Digital High-Voltage Insulation Tester | 250 / 500 / 1000 / 2500 V, up to 100 GΩ, PI / DAR, short-circuit current 1.5 mA250 / 500 / 1000 / 2500 V; up to 100.0 GΩ; ±5%rdg±3dgtPI / DAR diagnostics; short-circuit current 1.5 mA; automatic discharge after testingCAT IV 300 V / CAT III 600 V; 8 × C batteries; approx. 1.7 kgPrice on requestProject QuoteAdd to quote
KYORITSU2056RKYORITSU KEW 2056R AC/DC Clamp Meter | True RMS, AC / DC 1000 A, 600 V, φ40 mm jaw, CAT IV 600 V, NCVAC / DC 0–600.0 / 1000 A; AC / DC 600 V; True RMSφ40 mm jaw; 6039 counts with bar graph; NCV non-contact voltage detectionCAT IV 600 V; 2 × AAA; approx. 310 gPrice on requestProject QuoteAdd to quote
KYORITSU1009KYORITSU MODEL 1009 Digital Multimeter | 3999 counts, DC/AC 600 V, 10 A, 40 MΩ, capacitance 100 μF, frequency 10 MHz3999 counts; auto and manual rangingDC/AC 600 V; DC/AC 10 A; 40 MΩ; 100 μF; 10 MHzCAT III 300 V; 2 × AA; approx. 280 gPrice on requestProject QuoteAdd to quote
MUSASHIIP-701GMUSASHI INTECH IP-701G DC Withstand Voltage Tester | DC -0.5 to -37 kV, 0–200 µA, G-grounding method insulation deterioration diagnosis, battery/DC/AC powerOutput DC -0.5 to -37 kV (negative polarity); 0–200 µA (short-circuit current 1 mA)LCD voltmeter, ±1% +2 dgt at -36.00 kV; ammeter 2 µA–2 mA in four rangesBuilt-in rechargeable battery / DC 12–14 V / AC 90–240 V; approx. 8 kgPrice on requestProject QuoteAdd to quote
RAYTECHWR50-13Raytech WR50-13 Transformer Winding Resistance Tester | 50 A, 3 measurement channels, 0.00 µΩ–100 kΩ, core demagnetization, IP67 (lid closed)Output 25 mA–50 A, up to 50 VDC; charge/discharge up to 1500 H0.00 µΩ–100 kΩ; 30–50 A range ±0.1% ±0.05 µΩ3 measurement + 3 temperature channels; 5.7-inch touch; IP67 (lid closed); 16.6 kgPrice on requestProject QuoteAdd to quote
RAYTECHWR14Raytech WR14 Transformer Winding Resistance Tester | 15 A, 2 measurement channels, battery or mains, 0.00 µΩ–100 kΩ, 9.4 kgOutput 25 mA–15 A, up to 30 VDC; Li-ion battery 14.8 V / 6 Ah or mains0.00 µΩ–100 kΩ; 10–15 A range ±0.1% ±0.1 µΩ2 measurement + 2 temperature channels; 5.7-inch touch; IP67 (lid closed); 9.4 kgPrice on requestProject QuoteAdd to quote
RAYTECHTR-MARK III 250VRaytech TR-MARK III 250V Three-Phase Transformer Turns Ratio Tester | Ratio 0.8–45,000, test voltage up to 250 V, automatic vector group detectionRatio 0.8–45,000; ±0.06% for 0.8–5,000 at 250 VTest voltage 1/10/40/100/250 VAC; phase ±0.05°Automatic vector group and tap detection; 5.7-inch touch; IP67 (lid closed); 10.5 kgPrice on requestProject QuoteAdd to quote
RAYTECHTR-1Raytech TR-1 Single-Phase Transformer Turns Ratio Tester | Ratio 0.8–4,000, ±0.08%, battery or mains, IP67 (lid closed), 3.2 kgRatio 0.8–4,000; ±0.08% ±1 LSD for 0.8–100PT mode 1/5/10/40 VAC; CT mode 1–5 VAC, max. 1 ARechargeable battery, 1,000+ tests; IP67 (lid closed); 1 m drop; 3.2 kgPrice on requestProject QuoteAdd to quote
VANGUARDTRM-20Vanguard TRM-20 Transformer Winding Resistance Tester | Selectable 1–25 A, 1 µΩ–2,000 Ω, dual channel, automatic discharge and demagnetization, LTC testingTest current 1–25 A (1 A steps); 60 Vdc magnetization1 µΩ–2,000 Ω; ±0.5% ±1 count for 1–19,999 µΩDual channel; automatic discharge and demagnetization; RS-232C, USB, Bluetooth; 15.4 kgPrice on requestProject QuoteAdd to quote
VANGUARDTRF-100Vanguard TRF-100 Three-Phase Transformer Turns Ratio Tester | Ratio 0.8–50,000, 4/40/100 Vac, phase angle and excitation currentRatio 0.8–50,000; ±0.05% for 0.8–1,000 at 40/100 VacTest voltage 4 Vac, 40 Vac, 100 Vac; phase angle ±0.2°1,000 records; USB; optional 4.5-inch printer; 6.4 kgPrice on requestProject QuoteAdd to quote
VANGUARDAuto-Ohm 10Vanguard Auto-Ohm 10 Micro-Ohmmeter | 10 A true DC, 0.1 µΩ resolution, ±0.2%, approx. 2,900 tests per Li-ion chargeTest current 10 A / 5 A / 1 A / 100 mA / 10 mA / 1 mA0.1 µΩ resolution on 10 A range, ±0.2% ±0.2 µΩ; up to 5,000 Ω (1 mA)Li-ion battery approx. 2,900 tests (10 A / 2 s); 600 V protection; 3.54 kgPrice on requestProject QuoteAdd to quote
VANGUARDATRT-01B S3Vanguard ATRT-01B S3 Single-Phase Transformer Turns Ratio Tester | Ratio 0.8–15,000, 4/40 Vac, battery or mains, 4.3 kgRatio 0.8–15,000; accuracy 0.1% for 0.8–1,999Test voltage 4 Vac, 40 Vac; phase angle ±0.2°; excitation current 0–2 ALead-acid battery approx. 4 h or 90–240 Vac; RS-232C; 4.3 kgPrice on requestProject QuoteAdd to quote
MEGGERTTRU3Megger TTRU3 Three-Phase Transformer Turns Ratio Tester | Simultaneous three-phase excitation, step-up measurement up to 250 V, ±0.05%, 7-inch touchscreenRatio 0.8–50000 (step-down); ±0.05% for 0.8–1000 at 25–48 VSimultaneous three-phase excitation; step-up up to 250 V on primary (ADV: 125 V)7-inch touchscreen; IP51; 6.5 kg; USB exportPrice on requestProject QuoteAdd to quote
MEGGERTTRU1Megger TTRU1 Handheld Transformer Turns Ratio Tester | Single-phase measurement, up to 62.5 V induced, ±0.05%, IP54, approx. 1 kgSingle-phase step-down measurement; ratio 0.8–50000; ±0.05% for 0.8–1000 at 25–50 VInduced voltage BASIC 37.5 V, ADV 62.5 V; ADV adds short/open-circuit Go/No Go6 × AA (USB-C rechargeable NiMH included) approx. 1000 tests; IP54; approx. 1 kgPrice on requestProject QuoteAdd to quote
MEGGERTDR500/3Megger TDR500/3 Handheld Time Domain Reflectometer (TDR) | Metallic cable fault location, up to 5 km, 0.1 m resolution, 4 impedances, IP54Range 10 m–5 km in 7 steps; min. resolution 0.1 mOutput impedance 25/50/75/100 Ω; velocity factor 0.2–0.99; 2 ns pulse5 × AA approx. 14 h; IP54; 0.6 kgPrice on requestProject QuoteAdd to quote
MEGGEROTS PB/OTS AFMegger OTS PB/OTS AF Insulating Oil Breakdown Tester | Fully automatic, 60/80/100 kV, built-in IEC 60156, ASTM D877/D1816 and other standardsOTS60PB/OTS80PB: 60/80 kV, mains and NiMH battery, 16.8–20.8 kgOTS60AF/80AF/100AF: up to 100 kV, barcode scanner and alphanumeric keypad, 30 kgVoltage resolution 0.1 kV, ±1% ±2 dgt; 400 ml vessel; built-in printerPrice on requestProject QuoteAdd to quote
MEGGERMIT515Megger MIT515/MIT1025 High-Voltage Insulation Resistance Tester (discontinued by the manufacturer; current models MIT515/2, MIT1025/2) | 5 kV/10 kV, up to 20 TΩ, CAT IV 600 VMIT515: 5 kV, 10 TΩ, IR, IR(t), DAR, PI, no memoryMIT1025: 10 kV, 20 TΩ, adds SV, DD, Ramp, memory and USBDiscontinued; current models MIT515/2 (Essential), MIT1025/2 (Advanced)Price on requestProject QuoteAdd to quote
MEGGEREGIL200Megger EGIL200 Circuit Breaker Analyzer | 3/6/12 main and resistor contact channels, 3 auxiliary contact channels, 40 kHz sampling, DualGround, IP673, 6 or 12 main/resistor contact channels; 3 auxiliary contact channels; 40 kHz samplingControl outputs Close, Trip 1, Trip 2; coil current ±80 A; PIR 10 Ω–10 kΩ7-inch touchscreen; 12 kg; IP67 (lid closed); optional DCM200 both-sides groundingPrice on requestProject QuoteAdd to quote
MEGGERDLRO10HDMegger DLRO10HD 10 A Digital Low Resistance Ohmmeter | 0.1 μΩ resolution, 5 measurement modes, 600 V accidental connection without blowing fuses, IP65 (lid closed)100 μA–10 A; 0.1 μΩ resolution on 0–2.5 mΩ range; ±0.2% ±0.2 μΩ5 modes: bidirectional, unidirectional, auto, continuous, inductive; high-power 10 A up to 250 mΩ600 V accidental connection without blowing fuses; IP65 (lid closed) / IP54 (battery operation); 6.7 kgPrice on requestProject QuoteAdd to quote
MEGGERDELTA4000Megger DELTA4000 12 kV Dielectric Loss (Power Factor/tan δ) Test System | 1–505 Hz variable frequency, Individual Temperature Correction (ITC), 3.6 kVA0–12 kV; 3.6 kVA; 300 mA (4 minutes), 100 mA continuousFrequency 1–505 Hz (250 V), 15–400 Hz (4 kV), 45–70 Hz (12 kV)PF/DF ±(0.5% of reading + 0.02%); capacitance ±(0.5% + 0.1 pF); ITC temperature correctionPrice on requestProject QuoteAdd to quote
YOKOGAWAFX1000YOKOGAWA FX1000 Paperless Recorder | 2–12 universal input channels, 5.7-inch TFT, 400 MB internal + SD/CF card, IP65 front panel2/4/6/8/10/12 channels; universal inputs: DC voltage, thermocouple, RTD, DIDC voltage ±(0.05% rdg + 3–12 dgt); FX1002/FX1004 scan as fast as 125 ms5.7-inch TFT; 400 MB internal + SD/CF; IP65 front panel; 144×144 mmPrice on requestProject QuoteAdd to quote
YOKOGAWAWT310/WT332/WT333YOKOGAWA WT310/WT332/WT333 Digital Power Meter (WT300 series, discontinued by the manufacturer) | Replacement: WT300E seriesDiscontinued by the manufacturer on 2016-03-15; replacement WT300E seriesWT300: 0.1% rdg + 0.1% rng (50/60 Hz); DC, 0.5 Hz–100 kHzWT300E: WT310E/WT310EH/WT332E/WT333E, basic power accuracy ±0.15%Price on requestProject QuoteAdd to quote