Vanguard TRF-100 Three-Phase Transformer Turns Ratio Tester | Ratio 0.8–50,000, 4/40/100 Vac, phase angle and excitation current
Vanguard TRF-100 Three-Phase Transformer Turns Ratio Tester: 0.8–50,000 Overview The TRF-100 is Vanguard's third-generation microprocessor-based automatic three-phase transformer turns ratio tester. It determines the ratio by measuring no-load winding voltages per the IEEE C57.12.90 method and self-calibrates before each measurement, requiring no a
Overview
Vanguard TRF-100 Three-Phase Transformer Turns Ratio Tester: 0.8–50,000
Overview
The TRF-100 is Vanguard's third-generation microprocessor-based automatic three-phase transformer turns ratio tester. It determines the ratio by measuring no-load winding voltages per the IEEE C57.12.90 method and self-calibrates before each measurement, requiring no adjustment or temperature compensation. It recognizes 130 three-phase transformer types defined by ANSI, IEC and Australian standards, and measures phase angle and excitation current at the same time.
Key Specifications
- Measurement method: ANSI/IEEE C57.12.90
- Ratio range: 0.8–50,000
- Ratio accuracy (typical): 40/100 Vac: 0.8–1,000 ±0.05%, 1,001–4,000 ±0.1%, 4,001–15,000 ±0.25%, up to 50,000 ±0.5%; 4 Vac: 0.8–1,000 ±0.08%
- Test voltage: 4 Vac @ 1.0 A, 40 Vac @ 0.6 A, 100 Vac @ 0.1 A
- Excitation current: 0–2 A; ±1 mA ±2% of reading
- Phase angle: 0–360°; ±0.2°
- Display and storage: Backlit LCD, 20 characters × 4 lines; 1,000 transformer records, 128 test plans
- Interface and printing: USB; optional built-in 4.5-inch thermal printer; Windows analysis software included
- Power and dimensions: 100–120 or 200–240 Vac; 43.2 × 17.8 × 33.0 cm; 6.4 kg
Applications
- Ratio, polarity and phase acceptance testing of substation and distribution transformers.
- Transformer preventive maintenance and fault diagnosis.
Specifications per the specification table on the Vanguard TRF-100 product page (doble.com, retrieved 2026-10-23).
Specifications
- Key specifications
- Ratio 0.8–50,000; ±0.05% for 0.8–1,000 at 40/100 VacTest voltage 4 Vac, 40 Vac, 100 Vac; phase angle ±0.2°1,000 records; USB; optional 4.5-inch printer; 6.4 kg
- Model
- TRF-100
- Brand
- VANGUARD
- Purchasing
- In stock, tax incl. / B2B formal quotation request (RFQ)
- Warranty
- One-year manufacturer warranty
Calibration
If your instrument needs periodic calibration, register the brand, model and calibration requirements on the calibration service page and we will send a separate quote.
Go to calibration service