MEGGERTTRU3Megger TTRU3 Three-Phase Transformer Turns Ratio Tester | Simultaneous three-phase excitation, step-up measurement up to 250 V, ±0.05%, 7-inch touchscreenRatio 0.8–50000 (step-down); ±0.05% for 0.8–1000 at 25–48 VSimultaneous three-phase excitation; step-up up to 250 V on primary (ADV: 125 V)7-inch touchscreen; IP51; 6.5 kg; USB exportPrice on requestProject QuoteAdd to quote
MEGGERTTRU1Megger TTRU1 Handheld Transformer Turns Ratio Tester | Single-phase measurement, up to 62.5 V induced, ±0.05%, IP54, approx. 1 kgSingle-phase step-down measurement; ratio 0.8–50000; ±0.05% for 0.8–1000 at 25–50 VInduced voltage BASIC 37.5 V, ADV 62.5 V; ADV adds short/open-circuit Go/No Go6 × AA (USB-C rechargeable NiMH included) approx. 1000 tests; IP54; approx. 1 kgPrice on requestProject QuoteAdd to quote
MEGGERTDR500/3Megger TDR500/3 Handheld Time Domain Reflectometer (TDR) | Metallic cable fault location, up to 5 km, 0.1 m resolution, 4 impedances, IP54Range 10 m–5 km in 7 steps; min. resolution 0.1 mOutput impedance 25/50/75/100 Ω; velocity factor 0.2–0.99; 2 ns pulse5 × AA approx. 14 h; IP54; 0.6 kgPrice on requestProject QuoteAdd to quote
MEGGEROTS PB/OTS AFMegger OTS PB/OTS AF Insulating Oil Breakdown Tester | Fully automatic, 60/80/100 kV, built-in IEC 60156, ASTM D877/D1816 and other standardsOTS60PB/OTS80PB: 60/80 kV, mains and NiMH battery, 16.8–20.8 kgOTS60AF/80AF/100AF: up to 100 kV, barcode scanner and alphanumeric keypad, 30 kgVoltage resolution 0.1 kV, ±1% ±2 dgt; 400 ml vessel; built-in printerPrice on requestProject QuoteAdd to quote
MEGGERMIT515Megger MIT515/MIT1025 High-Voltage Insulation Resistance Tester (discontinued by the manufacturer; current models MIT515/2, MIT1025/2) | 5 kV/10 kV, up to 20 TΩ, CAT IV 600 VMIT515: 5 kV, 10 TΩ, IR, IR(t), DAR, PI, no memoryMIT1025: 10 kV, 20 TΩ, adds SV, DD, Ramp, memory and USBDiscontinued; current models MIT515/2 (Essential), MIT1025/2 (Advanced)Price on requestProject QuoteAdd to quote
MEGGEREGIL200Megger EGIL200 Circuit Breaker Analyzer | 3/6/12 main and resistor contact channels, 3 auxiliary contact channels, 40 kHz sampling, DualGround, IP673, 6 or 12 main/resistor contact channels; 3 auxiliary contact channels; 40 kHz samplingControl outputs Close, Trip 1, Trip 2; coil current ±80 A; PIR 10 Ω–10 kΩ7-inch touchscreen; 12 kg; IP67 (lid closed); optional DCM200 both-sides groundingPrice on requestProject QuoteAdd to quote
MEGGERDLRO10HDMegger DLRO10HD 10 A Digital Low Resistance Ohmmeter | 0.1 μΩ resolution, 5 measurement modes, 600 V accidental connection without blowing fuses, IP65 (lid closed)100 μA–10 A; 0.1 μΩ resolution on 0–2.5 mΩ range; ±0.2% ±0.2 μΩ5 modes: bidirectional, unidirectional, auto, continuous, inductive; high-power 10 A up to 250 mΩ600 V accidental connection without blowing fuses; IP65 (lid closed) / IP54 (battery operation); 6.7 kgPrice on requestProject QuoteAdd to quote
MEGGERDELTA4000Megger DELTA4000 12 kV Dielectric Loss (Power Factor/tan δ) Test System | 1–505 Hz variable frequency, Individual Temperature Correction (ITC), 3.6 kVA0–12 kV; 3.6 kVA; 300 mA (4 minutes), 100 mA continuousFrequency 1–505 Hz (250 V), 15–400 Hz (4 kV), 45–70 Hz (12 kV)PF/DF ±(0.5% of reading + 0.02%); capacitance ±(0.5% + 0.1 pF); ITC temperature correctionPrice on requestProject QuoteAdd to quote
MEGGERSVERKER 900Megger SVERKER 900 Three-Phase Relay and Substation Test System | 3 current + 4 voltage sources, single-phase mode 105 A / 900 V, DC and 10–600 Hz, operation without a PC3 × 35 A (10 s ON / 20 s OFF), 3 × 20 A continuous; 4 × 300 VSingle-phase mode: current in parallel 105 A, voltage in series 900 V; DC and 10–600 Hz5.7-inch touch screen; 6 binary inputs; 15.2 kgPrice on requestProject QuoteAdd to quote