Megger DELTA4000 12 kV Dielectric Loss (Power Factor/tan δ) Test System | 1–505 Hz variable frequency, Individual Temperature Correction (ITC), 3.6 kVA
MEGGERDELTA4000
[ICANSTron] Genuine authorized MEGGER product

Megger DELTA4000 12 kV Dielectric Loss (Power Factor/tan δ) Test System | 1–505 Hz variable frequency, Individual Temperature Correction (ITC), 3.6 kVA

Megger DELTA4000 12 kV Dielectric Loss Test System Overview The DELTA4000 is Megger's automatic 12 kV insulation power factor/dielectric loss (tan δ) test system. In addition to 50/60 Hz testing, it uses 1 Hz power factor to help assess insulation condition. It measures at variable frequencies from 1 to 505 Hz and applies Individual Temperature Cor

0–12 kV; 3.6 kVA; 300 mA (4 minutes), 100 mA continuousFrequency 1–505 Hz (250 V), 15–400 Hz (4 kV), 45–70 Hz (12 kV)PF/DF ±(0.5% of reading + 0.02%); capacitance ±(0.5% + 0.1 pF); ITC temperature correction
Corporate reference price (excl. tax)
Price on request
E-invoice issued after payment
One-year manufacturer warranty
Chat with Us on LINE

Overview

Megger DELTA4000 12 kV Dielectric Loss Test System

Overview

The DELTA4000 is Megger's automatic 12 kV insulation power factor/dielectric loss (tan δ) test system. In addition to 50/60 Hz testing, it uses 1 Hz power factor to help assess insulation condition. It measures at variable frequencies from 1 to 505 Hz and applies Individual Temperature Correction (ITC, patented by the manufacturer) based on the insulation under test itself. With optional accessories it can also test insulating oil and perform high-voltage TTR and CVT ratio tests.

Key Specifications

  • Output: 0–12 kV continuously adjustable; 3.6 kVA; 300 mA (4 minutes), 200 mA (30 minutes), 100 mA (continuous)
  • Frequency: 45–70 Hz (12 kV), 15–400 Hz (4 kV), 1–505 Hz (250 V)
  • Measurements: Voltage, current, capacitance, inductance, power factor, dissipation factor (tan δ), watt losses, excitation current, tip-up
  • Accuracy: Capacitance ±(0.5% of reading + 0.1 pF); PF/DF ±(0.5% of reading + 0.02%); voltage and current ±1% of reading
  • Interference immunity: Electrostatic interference 15 mA; electromagnetic 500 μT
  • Temperature correction: Individual Temperature Correction (ITC), 5–50 °C corrected to 20 °C
  • System configurations: DELTA4110 (DELTA4100 controller + DELTA4010B HV unit, connected to a PC); DELTA4310A (built-in computer and 12-inch touchscreen)
  • Dimensions and weight: Controller and HV unit each 290 × 290 × 460 mm; controller 14 kg (4300A: 17 kg), HV unit 23 kg

Applications

  • Insulation diagnostics of power transformers, bushings, circuit breakers, cables, surge arresters and rotating machines.

Specifications per the Megger product page and DELTA4000 datasheet (V020) (retrieved 2026-10-21).

Specifications

Key specifications
0–12 kV; 3.6 kVA; 300 mA (4 minutes), 100 mA continuousFrequency 1–505 Hz (250 V), 15–400 Hz (4 kV), 45–70 Hz (12 kV)PF/DF ±(0.5% of reading + 0.02%); capacitance ±(0.5% + 0.1 pF); ITC temperature correction
Model
DELTA4000
Brand
MEGGER
Purchasing
In stock, tax incl. / B2B formal quotation request (RFQ)
Warranty
One-year manufacturer warranty

Calibration

If your instrument needs periodic calibration, register the brand, model and calibration requirements on the calibration service page and we will send a separate quote.

Go to calibration service