Megger SVERKER 900 Three-Phase Relay and Substation Test System | 3 current + 4 voltage sources, single-phase mode 105 A / 900 V, DC and 10–600 Hz, operation without a PC
MEGGERSVERKER 900
[ICANSTron] Genuine authorized MEGGER product

Megger SVERKER 900 Three-Phase Relay and Substation Test System | 3 current + 4 voltage sources, single-phase mode 105 A / 900 V, DC and 10–600 Hz, operation without a PC

Megger SVERKER 900 Three-Phase Relay and Substation Test System Overview The SVERKER 900 is a Megger three-phase relay and substation test system, used mainly for manual three-phase secondary testing of protection equipment; the current and voltage sources can be connected in series or parallel for primary injection. The fourth voltage source can s

3 × 35 A (10 s ON / 20 s OFF), 3 × 20 A continuous; 4 × 300 VSingle-phase mode: current in parallel 105 A, voltage in series 900 V; DC and 10–600 Hz5.7-inch touch screen; 6 binary inputs; 15.2 kg
Corporate reference price (excl. tax)
Price on request
E-invoice issued after payment
One-year manufacturer warranty
Chat with Us on LINE

Overview

Megger SVERKER 900 Three-Phase Relay and Substation Test System

Overview

The SVERKER 900 is a Megger three-phase relay and substation test system, used mainly for manual three-phase secondary testing of protection equipment; the current and voltage sources can be connected in series or parallel for primary injection. The fourth voltage source can simulate a busbar reference voltage for testing numerical relays. It is operated via a touch screen, with no PC needed on site.

Key Specifications

  • Current outputs: 3 × 35 A (AC / DC, 10 s ON / 20 s OFF, at least 15 times); 3 × 20 A continuous; 3 × 277 VA
  • Voltage outputs: 4 × 300 V (AC / DC); 4 × 125 VA
  • Single-phase mode: Current in parallel up to 105 A (721 VA); voltage in series up to 900 V (450 VA)
  • Frequency and phase: DC, 10–600 Hz; phase 0–360°
  • Measurement: Built-in voltmeter 0–900 V, ammeter 0–10 A; 6 binary inputs with timing; impedance, power, power factor
  • Test functions: Timing, multi-timing (MTT), CT excitation curve, Prefault-Fault, ramp, sequence and impedance tests
  • General: 5.7-inch touch screen; 100–240 V AC; 350 × 270 × 220 mm, 15.2 kg

Applications

  • Commissioning and maintenance of protection relays in distribution substations, renewable energy plants and industrial power distribution.
  • CT excitation curve, CT / VT ratio and polarity tests.

Specifications per the Megger product page and SVERKER 900 datasheet (V19) (retrieved 2026-10-21).

Specifications

Key specifications
3 × 35 A (10 s ON / 20 s OFF), 3 × 20 A continuous; 4 × 300 VSingle-phase mode: current in parallel 105 A, voltage in series 900 V; DC and 10–600 Hz5.7-inch touch screen; 6 binary inputs; 15.2 kg
Model
SVERKER 900
Brand
MEGGER
Purchasing
In stock, tax incl. / B2B formal quotation request (RFQ)
Warranty
One-year manufacturer warranty

Calibration

If your instrument needs periodic calibration, register the brand, model and calibration requirements on the calibration service page and we will send a separate quote.

Go to calibration service