HIOKI FT6041 Earth Tester | 2/3/4-pole methods, MEC without disconnecting electrodes, 2-clamp method, IP65/IP67, CAT IV 100 V, optional Z3210 Bluetooth
HIOKI FT6041 Earth Tester: MEC Method Without Disconnecting Electrodes, IP65/IP67 Overview The FT6041 supports the 2-pole, 3-pole and 4-pole electrode methods, and with the MEC method (the 3-pole method plus a clamp sensor to measure current) it can measure a single ground electrode within a multi-grounded system without disconnecting the electrode
Overview
HIOKI FT6041 Earth Tester: MEC Method Without Disconnecting Electrodes, IP65/IP67
Overview
The FT6041 supports the 2-pole, 3-pole and 4-pole electrode methods, and with the MEC method (the 3-pole method plus a clamp sensor to measure current) it can measure a single ground electrode within a multi-grounded system without disconnecting the electrode or shutting off power. Where auxiliary ground rods cannot be driven into the ground, the standard ground net module L9846 can be used. Safety rating CAT IV 100V/CAT III 150V/CAT II 300V; dust- and waterproof to IP65/IP67.
Key Specifications
- Ranges: Electrode methods 0–300.0 kΩ (3 Ω–300 kΩ, 6 ranges, 0.001 Ω resolution on the 3 Ω range); clamp 0.02 Ω–500 Ω; low resistance 0–3000 Ω.
- MEC method and 2-clamp method: Require clamp sensors (FT9847, CT9848 are options; the FT6041-91 is a kit with sensors).
- Ground net module: L9846 included as standard, for concrete, asphalt and other surfaces where stakes cannot be driven.
- Safety and protection: CAT IV 100V/CAT III 150V/CAT II 300V; IP65/IP67; operating temperature -25–65°C.
- Wireless: With the optional Z3210, data can be sent via Bluetooth to GENNECT Cross or entered directly into Excel.
- Power and weight: Ni-MH batteries ×4, approx. 500 measurements with the 3-pole method; approx. 765 g.
Applications
- Testing of substation and factory ground grids and lightning protection grounding.
- Measurement of single ground electrodes in multi-grounded systems at cell sites and buildings.
Specifications per the HIOKI product page (retrieved 2026-10-20).
Specifications
- Key specifications
- Electrode methods 0–300.0 kΩ (0.001 Ω resolution on the 3 Ω range)MEC method without disconnecting electrodes, 2-clamp method; ground net module L9846 includedIP65/IP67; CAT IV 100 V/CAT III 150 V/CAT II 300 V
- Model
- FT6041
- Brand
- HIOKI
- Purchasing
- In stock, tax incl. / Credit card and convenience-store payment supported
- Warranty
- One-year manufacturer warranty
Calibration
If your instrument needs periodic calibration, register the brand, model and calibration requirements on the calibration service page and we will send a separate quote.
Go to calibration service